[Oct-2023] NSE7_LED-7.0 Braindumps - NSE7_LED-7.0 Questions to Get Better Grades [Q15-Q30]

Share

[Oct-2023] NSE7_LED-7.0 Braindumps – NSE7_LED-7.0 Questions to Get Better Grades

NSE7_LED-7.0 Exam Dumps - Try Best NSE7_LED-7.0 Exam Questions - Test4Sure


Fortinet NSE7_LED-7.0 certification exam consists of multiple-choice questions and requires the candidates to have a deep understanding of the Fortinet Security Fabric and its implementation in a LAN Edge environment. NSE7_LED-7.0 exam is a challenging one, and the candidates need to have hands-on experience with the Fortinet Security Fabric to pass the exam.


The Fortinet NSE 7 - LAN Edge 7.0 certification exam covers a wide range of topics, including Fortinet security technologies, network security concepts, and best practices in LAN edge security. It tests the candidate's ability to configure, manage, and troubleshoot Fortinet security solutions, including FortiGate, FortiSwitch, and FortiAP devices. NSE7_LED-7.0 exam also evaluates the candidate's knowledge of network protocols, security policies, and advanced security features such as VPN, SSL, and IPSec. Passing the Fortinet NSE7_LED-7.0 exam is a prerequisite for achieving the Fortinet NSE 7 certification, which is recognized globally as a standard of excellence in network security expertise.

 

NEW QUESTION # 15
Refer to the exhibit.

By default FortiOS creates the following DHCP server scope for the FortiLink interface as shown in the exhibit What is the objective of the vci-string setting?

  • A. To restrict the IP address assignment to devices that have FortiSwitch or FortiExtender as their hostname
  • B. To ignore DHCP requests coming from FortiSwitch and FortiExtender devices
  • C. To restrict the IP address assignment to FortiSwitch and FortiExtender devices
  • D. To reserve IP addresses for FortiSwitch and FortiExtender devices

Answer: C

Explanation:
Explanation
According to the exhibit, the DHCP server scope for the FortiLink interface has a vci-string setting with the value "Cisco AP c2700". This setting is used to match the vendor class identifier (VCI) of the DHCP clients that request an IP address from the DHCP server. The VCI is a text string that uniquely identifies a type of vendor device. Therefore, option C is true because the vci-string setting restricts the IP address assignment to FortiSwitch and FortiExtender devices, which use the VCI "Cisco AP c2700". Option A is false because the vci-string setting does not ignore DHCP requests coming from FortiSwitch and FortiExtender devices, but rather accepts them. Option B is false because the vci-string setting does not reserve IP addresses for FortiSwitch and FortiExtender devices, but rather assigns them dynamically. Option D is false because the vci-string setting does not restrict the IP address assignment to devices that have FortiSwitch or FortiExtender as their hostname, but rather to devices that have "Cisco AP c2700" as their VCI.


NEW QUESTION # 16
Refer to the exhibit.

Examine the FortiSwitch security policy shown in the exhibit
If the security profile shown in the exhibit is assigned to all ports on a FortiSwitch device for 802 1X authentication which statement about the switch is correct?

  • A. FortiSwitch will assign non-802 1X devices to the onboarding VLAN
  • B. All EAP messages will be terminated on FortiSwitch
  • C. FortiSwitch will try to authenticate non-802 1X devices using the device MAC address as the username and password
  • D. FortiSwitch cannot authenticate multiple devices connected to the same port

Answer: A

Explanation:
Explanation
According to the FortiSwitch Administration Guide, "If a device does not support 802.1X authentication, you can configure the switch to assign the device to an onboarding VLAN. The onboarding VLAN is a separate VLAN that you can use to provide limited network access to non-802.1X devices." Therefore, option C is true because it describes the behavior of FortiSwitch when the security profile shown in the exhibit is assigned to all ports. Option A is false because FortiSwitch can authenticate multiple devices connected to the same port using MAC-based or MAB-EAP modes. Option B is false because FortiSwitch will not try to authenticate non-802.1X devices using the device MAC address as the username and password, but rather use MAC authentication bypass (MAB) or EAP pass-through modes. Option D is false because all EAP messages will be terminated on FortiGate, not FortiSwitch, when using 802.1X authentication.


NEW QUESTION # 17
Refer to the exhibit

Examine the FortiGate RSSO configuration shown in the exhibit
FortiGate is configured to receive RADIUS accounting messages on port3 to authenticate RSSO users The users are located behind port3 and the internet link is connected to port1 FortiGate is processing incoming RADIUS accounting messages successfully and RSSO users are getting associated with the RSSO Group user group However all the users are able to access the internet, and the administrator wants to restrict internet access to RSSO users only Which configuration change should the administrator make to fix the problem?

  • A. Create a second firewall policy from port3 lo port1 and select the target destination subnets
  • B. Enable Security Fabric Connection on port3
  • C. Change the RADIUS Attribute Value selling to match the name of the RADIUS attribute containing the group membership information of the RSSO users
  • D. Add RSSO Group to the firewall policy

Answer: D

Explanation:
Explanation
According to the exhibit, the firewall policy from port3 to port1 has no user group specified, which means that it allows all users to access the internet. Therefore, option B is true because adding RSSO Group to the firewall policy will restrict internet access to RSSO users only. Option A is false because changing the RADIUS Attribute Value setting will not affect the firewall policy, but rather the RSSO user group membership. Option C is false because enabling Security Fabric Connection on port3 will not affect the firewall policy, but rather the communication between FortiGate and other Security Fabric devices. Option D is false because creating a second firewall policy from port3 to port1 will not affect the existing firewall policy, but rather create a redundant or conflicting policy.


NEW QUESTION # 18
Refer to the exhibits

The exhibits show the wireless network (VAP) SSID profiles defined on FortiManager and an AP profile assigned to a group of APs that are supported by FortiGate None of the APs are broadcasting the SSlDs defined by the AP profile Which changes do you need to make to enable the SSIDs to broadcast?

  • A. Enable one channel in the Channels section
  • B. In the SSIDs section enable Tunnel
  • C. Enable multiple channels in the Channels section and enable Radio Resource Provision
  • D. In the SSIDs section enable Manual and assign the networks manually

Answer: A

Explanation:
Explanation
According to the FortiManager Administration Guide1, "To enable the SSID, you must select at least one channel for the radio. If no channels are selected, the SSID will not be enabled." Therefore, enabling one channel in the Channels section will allow the SSIDs to broadcast.


NEW QUESTION # 19
Refer to the exhibits.

Exhibit.

Examine the troubleshooting outputs shown in the exhibits
Users have been reporting issues with the speed of their wireless connection in a particular part of the wireless network The interface that is having issues is the 2 4 GHz interface that is currently configured on channel 6 The administrator of the wireless network has investigated and surveyed the local RF environment using the tools available at the AP and FortiGate Which configuration would improve the wireless connection?

  • A. Change the AP 2 4 GHz channel to 1.
  • B. Change the AP 2 4 GHz channel to 9.
  • C. Change the AP 2 4 GHz channel to 13.
  • D. Change the AP 2 4 GHz channel to 11

Answer: A

Explanation:
Explanation
According to the exhibits, the AP 2.4 GHz interface is currently configured on channel 6, which is overlapping with other nearby APs on channels 4 and 8. This can cause interference and reduce the wireless performance.
Therefore, changing the AP 2.4 GHz channel to 1 would improve the wireless connection, as it would avoid the overlapping channels and use a non-overlapping channel instead. Option A is false because changing the AP 2.4 GHz channel to 11 would still overlap with other nearby APs on channels 9 and 13. Option C is false because changing the AP 2.4 GHz channel to 9 would still overlap with other nearby APs on channels 6, 8, and 11. Option D is false because changing the AP 2.4 GHz channel to 13 would still overlap with other nearby APs on channels 9 and 11.


NEW QUESTION # 20
An administrator is testing the connectivity for a new VLAN The devices in the VLAN are connected to a FortiSwitch device that is managed by FortiGate Quarantine is disabled on FortiGate While testing the administrator noticed that devices can ping FortiGate and FortiGate can ping the devices The administrator also noticed that inter-VLAN communication works However intra-VLAN communication does not work Which scenario is likely to cause this issue?

  • A. The native VLAN configured on the ports is incorrect
  • B. The FortiSwitch MAC address table is missing entries
  • C. The FortiGate ARP table is missing entries
  • D. Access VLAN is enabled on the VLAN

Answer: B

Explanation:
Explanation
According to the scenario, the devices in the VLAN are connected to a FortiSwitch device that is managed by FortiGate. Quarantine is disabled on FortiGate, which means that the devices are not blocked by any security policy. The devices can ping FortiGate and FortiGate can ping the devices, which means that the IP connectivity is working. Inter-VLAN communication works, which means that the routing between VLANs is working. However, intra-VLAN communication does not work, which means that the switching within the VLAN is not working. Therefore, option C is true because the FortiSwitch MAC address table is missing entries, which means that the FortiSwitch does not know how to forward frames to the destination MAC addresses within the VLAN. Option A is false because access VLAN is enabled on the VLAN, which means that the VLAN ID is added to the frames on ingress and removed on egress. This does not affect intra-VLAN communication. Option B is false because the native VLAN configured on the ports is incorrect, which means that the frames on the native VLAN are not tagged with a VLAN ID. This does not affect intra-VLAN communication. Option D is false because the FortiGate ARP table is missing entries, which means that FortiGate does not know how to map IP addresses to MAC addresses. This does not affect intra-VLAN communication.


NEW QUESTION # 21
Which two statements about the guest portal on FortiAuthenticator are true? (Choose two.)

  • A. Each remote user on FortiAuthenticator can sponsor up to 10 guest accounts
  • B. Administrators can use one or more incoming parameters to configure a mapping rule for the guest portal
  • C. The guest portal provides pre and post-log in services
  • D. Administrators must approve all guest accounts before they can be used

Answer: B,C

Explanation:
Explanation
According to the FortiAuthenticator Administration Guide2, "The guest portal provides pre and post-log in services for users (such as password reset and token registration abilities), and rules and replacement messages can be configured." Therefore, option C is true. The same guide also states that "Administrators can use one or more incoming parameters to configure a mapping rule for the guest portal." Therefore, option D is true.
Option A is false because remote users can sponsor any number of guest accounts, as long as they do not exceed the maximum number of guest accounts allowed by the license. Option B is false because administrators can choose to approve or reject guest accounts, or enable auto-approval.


NEW QUESTION # 22
A wireless network in a school provides guest access using a captive portal to allow unregistered users to self-register and access the network The administrator is requested to update the existing configuration to provide captive portal authentication through a secure connection (HTTPS) Which two changes must the administrator make to enforce HTTPS authentication"? (Choose two >

  • A. Create a new SSID with the HTTPS captive portal URL
  • B. Update the captive portal URL to use HTTPS on FortiGate and FortiAuthenticator
  • C. Enable HTTP redirect in the user authentication settings
  • D. Disable HTTP administrative access on the guest SSID to enforce HTTPS connection

Answer: B,C

Explanation:
Explanation
According to the FortiGate Administration Guide, "To enable HTTPS authentication, you must enable HTTP redirect in the user authentication settings. This redirects HTTP requests to HTTPS. You must also update the captive portal URL to use HTTPS on both FortiGate and FortiAuthenticator." Therefore, options B and D are true because they describe the changes that the administrator must make to enforce HTTPS authentication for the captive portal. Option A is false because creating a new SSID with the HTTPS captive portal URL is not required, as the existing SSID can be updated with the new URL. Option C is false because disabling HTTP administrative access on the guest SSID will not enforce HTTPS connection, but rather block HTTP connection.


NEW QUESTION # 23
Which two statements about FortiSwitchmanager are true1? (Choose two)

  • A. If the administrator makes any changes on FortiSwitch manager they must also install those changes on FortiGate so that those changes are applied on the managed switches
  • B. Per-device management is the default management mode on FortiManager
  • C. Any switch discovered or authorized on FortiGate must be added manually on FortiSwitch manager
  • D. FortiManager obtains the FortiSwitch status information by querying the FortiGate REST API every three minutes

Answer: A,D

Explanation:
Explanation
According to the FortiManager Administration Guide1, "FortiManager obtains the FortiSwitch status information by querying the FortiGate REST API every three minutes." Therefore, option B is true because it describes how FortiManager gets the information about the managed switches. According to the same guide2,
"If you make any changes in this module, you must install them on your managed device so that they are applied on your managed switches." Therefore, option C is true because it describes what the administrator must do after making any changes on FortiSwitch manager. Option A is false because central management is the default management mode on FortiManager, not per-device management. Option D is false because anyswitch discovered or authorized on FortiGate will be automatically added on FortiSwitch manager, not manually.
1: https://docs.fortinet.com/document/fortimanager/7.0.0/administration-guide/734537/fortiswitch-manager 2:
https://docs.fortinet.com/document/fortimanager/7.0.0/administration-guide/734537/fortiswitch-manager#fortisw


NEW QUESTION # 24
Refer to the exhibit.

Examine the network diagram and packet capture shown in the exhibit
The packet capture was taken between FortiGate and FortiAuthenticator and shows a RADIUS Access-Request packet sent by FortiSwitch to FortiAuthenticator through FortiGate Why does the User-Name attribute in the RADIUS Access-Request packet contain the client MAC address?

  • A. The client is performing AD machine authentication
  • B. The client is performing user authentication
  • C. FortiSwitch is sending a RADIUS accounting message to FortiAuthenticator
  • D. FortiSwitch is authenticating the client using MAC authentication bypass

Answer: D

Explanation:
Explanation
According to the exhibit, the User-Name attribute in the RADIUS Access-Request packet contains the client MAC address of 00:0c:29:6a:2b:3d. This indicates that FortiSwitch is authenticating the client using MAC authentication bypass (MAB), which is a method of authenticating devices that do not support 802.1X by using their MAC address as the username and password. Therefore, option B is true because it explains why the User-Name attribute contains the client MAC address. Option A is false because AD machine authentication uses a computer account name and password, not a MAC address. Option C is false because user authentication uses a user name and password, not a MAC address. Option D is false because FortiSwitch is sending a RADIUS Access-Request message to FortiAuthenticator, not a RADIUS accounting message.


NEW QUESTION # 25
Refer to the exhibit.

Examine the IPsec VPN phase 1 configuration shown in theexhibit
An administrator wants to use certificate-based authentication for an IPsec VPN user Which three configuration changes must you make on FortiGate to perform certificate-based authentication for the IPsec VPN user? (Choose three)

  • A. Create a PKI user for the IPsec VPN user, and then configure the IPsec VPN tunnel to accept the PKI user as peer certificate
  • B. Import the CA that signed the user certificate
  • C. Enable XAUTH on the IPsec VPN tunnel
  • D. In the Authentication section of the IPsec VPN tunnel in the Method drop-down list select Signature and then select the certificate that FortiGate will use for IPsec VPN
  • E. In the IKE section of the IPsec VPN tunnel in the Mode field select Main (ID protection)

Answer: B,C,D

Explanation:
Explanation
According to the FortiGate Administration Guide, "To use certificate-based authentication, you must configure the following settings on both peers: Select Signature as the authentication method and select a certificate to use for authentication. Import the CA certificate that issued the peer's certificate. Enable XAUTH on the phase 1 configuration." Therefore, options B, D, and E are true because they describe the configuration changes that must be made on FortiGate to perform certificate-based authentication for the IPsec VPN user.
Option A is false because creating a PKI user for the IPsec VPN user is not required, as the user certificate can be verified by the CA certificate. Option C is false because changing the IKE mode to Main (ID protection) is not required, as the IKE mode can be either Main or Aggressive for certificate-based authentication.


NEW QUESTION # 26
Exhibit.

Refer to the exhibit showing a network topology and SSID settings.
FortiGate is configured to use an external captive portal However wireless users are not able to see the captive portal login page Which configuration change should the administrator make to fix the problem?

  • A. Enable the captive-portal-exempt option in the firewall policy with the ID 12
  • B. Add the FortiAuthenticator and WindowsAD address objects as exempt destinations services
  • C. Remove the guest.portal user group in the firewall policy with the ID 12
  • D. Enable NAT in the firewall policy with the ID 13.

Answer: B

Explanation:
Explanation
According to the exhibit, the network topology and SSID settings show that FortiGate is configured to use an external captive portal hosted on FortiAuthenticator, which is connected to a Windows AD server for user authentication. However, wireless users are not able to see the captive portal login page, which means that they are not redirected to the external captive portal URL. Therefore, option B is true because adding the FortiAuthenticator and WindowsAD address objects as exempt destinations services will allow the wireless users to access the external captive portal URL without being blocked by the firewall policy. Option A is false because enabling NAT in the firewall policy with the ID 13 will not affect the redirection to the external captive portal URL, but rather the source IP address of the wireless traffic. Option C is false because enabling the captive-portal-exempt option in the firewall policy with the ID 12will bypass the captive portal authentication for the wireless users, which is not the desired outcome. Option D is false because removing the guest.portal user group in the firewall policy with the ID 12 will prevent the wireless users from being authenticated by FortiGate, which is required for accessing the external captive portal.


NEW QUESTION # 27
Refer to the exhibit

A device connected to port2 on FortiSwitch cannot access the network The port is assigned a security policy to enforce 802 1X authentication While troubleshooting the issue, the administrator obtains the debug output shown in the exhibit Which two scenarios are likely to cause this issue? (Choose two.)

  • A. The device is not configured for 802 IX authentication.
  • B. The device has been quarantined for 3600 seconds.
  • C. The device does not support 802 1X authentication
  • D. The device has been assigned the guest VLAN

Answer: A,C

Explanation:
Explanation
According to the exhibit, the debug output shows that the device connected to port2 on FortiSwitch is sending an EAPOL-Start message, which is the first step of the 802.1X authentication process. However, the output also shows that the device is not sending any EAP-Response messages, which are required to complete the authentication process. Therefore, option A is true because the device is not configured for 802.1X authentication, which means that it does not have the correct credentials or settings to authenticate with the RADIUS server. Option D is also true because the device does not support 802.1X authentication, which means that it does not have the capability or software to perform 802.1X authentication. Option B is false because the device has not been quarantined for 3600 seconds, but rather has a session timeout of 3600 seconds, which is the default value for 802.1X sessions. Option C is false because the device has not been assigned the guest VLAN, but rather has been assigned the default VLAN, which is VLAN 1.


NEW QUESTION # 28
Which CLI command should an administrator use to view the certificate verification process in real time?

  • A. diagnose debug application fnbamd -1
  • B. diagnose debug application authd -1
  • C. diagnose debug application foauthd -1
  • D. diagnose debug application radiusd -1

Answer: C

Explanation:
Explanation
According to the FortiOS CLI Reference Guide, "The diagnose debug application foauthd command enables debugging of certificate verification process in real time." Therefore, option A is true because it describes the CLI command that an administrator should use to view the certificate verification process in real time. Option B is false because diagnose debug application radiusd -1 enables debugging of RADIUS authentication process, not certificate verification process. Option C is false because diagnose debug application authd -1 enables debugging of authentication daemon process, not certificate verification process. Option D is false because diagnose debug application fnbamd -1 enables debugging of FSSO daemon process, not certificate verification process.


NEW QUESTION # 29
Refer to the exhibit.

Examine the FortiManager configuration and FortiGate CLI output shown in the exhibit An administrator is testing the NAC feature The test device is connected to a managed FortiSwitch device
{S224EPTF19"53C7)onpOrt2
After applying the NAC policy on port2 and generating traffic on the test device the test device is not matching the NAC policy therefore the test device remains m the onboarding VLAN Based on the information shown in the exhibit which two scenarios are likely to cause this issue? (Choose two.)

  • A. Management communication between FortiGate and FortiSwitch is down
  • B. The device operating system detected by FortiGate is not Linux
  • C. The MAC address configured on the NAC policy is incorrect
  • D. Device detection is not enabled on VLAN 4089

Answer: A,C

Explanation:
Explanation
According to the FortiManager configuration, the NAC policy is set to match devices with the MAC address of 00:0c:29:6a:2b:3c and the operating system of Linux.However, according to the FortiGate CLI output, the test device has a different MAC address of 00:0c:29:6a:2b:3d. Therefore, option B is true. Option A is also true because the FortiSwitch device status is shown as down, which means that the management communication between FortiGate and FortiSwitch is not working properly. This could prevent the NAC policy from being applied correctly. Option C is false because the device operating system detected by FortiGate is Linux, which matches the NAC policy. Option D is false because device detection is enabled on VLAN 4089, as shown by the command "config switch-controller vlan".


NEW QUESTION # 30
......

Verified NSE7_LED-7.0 exam dumps Q&As with Correct 40 Questions and Answers: https://freecert.test4sure.com/NSE7_LED-7.0-exam-materials.html